Some Default OILs at Emergency Situation in AP1000 NPP
-
摘要: 根据IAEA-TECDOC-955和相关文章提供的用于计算核电厂核事故应急情况下操作干预水平(OIL)的公式,利用RASCAL4.2计算程序,分别计算AP1000堆型假想的不同严重事故类型及其事故特征下的OIL1和OIL2默认值,并讨论了AP1000堆型相关设计特点对OIL1和OIL2默认值的影响。Abstract: Based on the formulae presented in IAEA-TECDOC-955 and the related article for operational intervention levels(OILs) at the emergency situation in nuclear power plants(NPPs),and by RASCAL 4.2 computer code,this paper calculates the default OIL1 and OIL2 for all kinds of postulated severe accidents of an AP1000 NPP.The effects on OIL1 and OIL2 calculation results of related AP1000 design features are also discussed.
-
Key words:
- AP1000 /
- Emergency /
- Operational Intervention Level(OIL) /
- Protective action
-