Experimental Study of Performance Parameters of a Fluid Densimeter with Vibrated Conduit
-
摘要: 通过单相水实验及改变气-液两相流含气量模拟不同流体密度的实验,研究振动、流量、压力对单直管振动式流体密度计测量性能的影响。结果表明,振动管横向平行振动模式较绕中心点的转动模式更适合用于密度测量;流量的变化对密度测量几乎没有影响,而系统振动、管内压力对流体密度测量的影响不可忽略。文中还给出了修正压力变化对测量结果影响修正关系式。Abstract: Experimental study of performance parameters of a fluid densimeter with vibrated conduit was carried out,using single-phase water and air-water two-phase flow with different vapor quality to modulate the fluid of different density.The results indicated that the parallel vibrating model of the vibrated conduit is more suitable for measuring the fluid density than the wiggling mode around the center of the vibrated conduit.The measuring of the fluid density is under the influence of the oscillation of the system and the pressure of the fluid.System oscillation should be limited and expressions modified by fluid pressure are presented.The experimental results also indicated that the change of the flowrate nearly has no impact on the performance parameters of the fluid densimeter with vibrated conduit.
-
Key words:
- Oscillated conduit /
- Densimeter /
- Fluid
-
计量
- 文章访问数: 14
- HTML全文浏览量: 5
- PDF下载量: 0
- 被引次数: 0