Abstract:
During the fabrication and tubing of the tube bundle for steam generator, some local deformations in the U-bend area might occur, which will result in a smaller gap or even contact between tubes. According to the design principles for tube bundle, taking CPR1000 steam generator(Type 55/19B) as the analysis model, the gap for the U-bends is analyzed and evaluated from the views of flow-induced vibration(FIV), wear, dry-out and stress analysis. Based on the analysis results, it is concluded that the minimum gap for the U-bends should be larger than the turbulent amplitudes to avoid unacceptable flow-induced vibration, wear and dry-out which means enough safety margins should be considered during U-bends gap design.