Discussion about Relation between “A” Type EOP for PWR and Emergency Classification Level
-
摘要: 根据应急操作规程(EOP)与应急行动水平(EAL)的共性,以方家山核电工程1号反应堆EOP为例,将EOP中的指示和参数与NEI 99-01中的EAL进行比较,对在执行"A"型事故规程时核电厂应进入的应急状态等级进行分析讨论,以便在制定核电厂的EAL时能充分利用EOP中给出的信息。
-
关键词:
- 核电厂应急 /
- 应急行动水平(EAL) /
- 应急操作规程(EOP) /
- “A”型
Abstract: The EOP for the first reactor of Fangjiashan Nuclear Power Plant is taken as an example in this paper. The indications and the parameters in the EOP are compared with the EAL in NEI 99-01 to discuss which emergency classification level the plant should be into when the "A" type EOP is implemented. Developing the EAL, the indications and the parameters should be taken into account. -
计量
- 文章访问数: 6
- HTML全文浏览量: 2
- PDF下载量: 0