Studies on Cross Connection between CEPR Auxiliary Power Supply Systems
-
摘要: 台山核电中国先进压水堆(CEPR)是世界上先进的三代核电技术。根据安全负荷冗余要求,CEPR核岛厂用电系统配置为相互独立的4列。不同种类的交叉供电设计,保证4列工艺系统安全负荷冗余运行符合要求,为各独立列维修提供照明、电源等,是保证4列冗余条件下缩短维修时间的必要手段。机械联锁确保交叉供电正常切换和运行,并通过"特殊条件"保证了和CEPR隔离原则和运行技术规范的一致性。Abstract: Taishan CEPR is the third- generation advanced pressure water reactor. According to the redundancy requirements of safety consumers, the auxiliary power supply system in the nuclear island sets up as 4 independent trains. Different cross-connection between four trains can make sure that the safety consumers work as the redundancy requirement, and provide lighting and power for maintenance, which is the condition for improving the maintenance efficiency. Mechanical interlocking is the method to manage the switch-over between the cross-connection. "Special condition" can make sure the consistence between cross-connection and CEPR separation rule and operation technical specification.
-