Configuration of Mobile Diesel Generator Vehicle for Nuclear Power Plants in Qinshan Region
-
摘要: 根据秦山地区核电厂余热排出典型成功路径和所需要的负荷容量,采用3种不同的计算方法,进行柴油发电机容量选择计算和选型分析。选择容量较小的柴油机配合容量较大的发电机的方式,可以满足核电厂直接启动大容量电动机的启动电压降等要求,解决了柴油机容量太大不能做成移动柴油发电机车的难题。分析了移动柴油发电车设置应急/试验选择装置等主要考虑的因素。Abstract: Based on the typical successful path and the required load capacity for the removal of residual heat for the nuclear power plants in Qinshan region, three different methods are adopted to calculate the diesel generator capacity and analyze the selection. Selection of the diesel with smaller capacity and the generator with larger capacity can satisfy the allowable bus voltage drop when the plant directly starts the large capacity motor. It solves the difficult problem that the large capacity diesel cannot be incorporated into a mobile diesel generator vehicle. This paper analyzes the main considerable factors for a mobile diesel generator vehicle, such as the emergency and test selection switch.
-
Key words:
- Mobile diesel generator vehicle /
- Load analysis /
- Model selection
-