Abstract:
During the pre-service eddy current inspection(PSI) of the steam generator of a power station, it was determined that the anti-vibration bars(AVBs) No.3 shifted from the design location to the cold side by approximately 10 degrees. Based on the specific flow induced analysis program GERBOISE, flow elastic characteristic, turbulence excitation response and fretting wear of the tube bundle for both AVBs design and shifted locations are calculated. By comparison of the calculated results of design and shifted conditions, the effects of AVBs shift on flow induced vibration and fretting wear are evaluated. The evaluated conclusion is that the shifted AVBs will not lead to the unaccepted flow induced vibration response and excessive fretting wear for the heat transfer tube.