Application of Main Pump Lifting Device in Nuclear Power Plant NCC&CFT
-
摘要: 简要介绍中国改进型三环路压水堆(CPR100)核电厂一回路冲洗试验(NCC)和冷态功能试验(CFT)中主泵的安装调试现状。在核电厂主泵电机缺位的情况下,对主泵转子提升装置进行了使用试验,结果表明该提升装置安全可靠、性能优异,可推广至CPR100及欧洲先进压水堆(EPR)核电厂项目建设,以降低施工风险。Abstract: CPR1000 nuclear power plant primary circle washing test(NCC) and cool function test(CFT) set and commissioning is introduced.Without the nuclear power plant main pump motor,a test on use of main pump rotor lift device shows that it is safe and reliable.This lift device can be used in CPR and EPR nuclear power plants to reduce the project risks.
-
Key words:
- Main pump motor /
- NCC /
- CFT /
- Lift shaft /
- Alignment automatically
-