Defects Analysis of CRDM Weld in EPR Nuclear Power Plants
-
摘要: 核电厂控制棒驱动机构(CRDM)长期处于高温、高压和高辐射环境中,其耐压壳异种金属焊缝容易出现裂纹等缺陷,是大修期间在役检查的关注重点。针对该焊缝役前超声检查中发现的疑似缺陷显示,通过补充目视、射线、超声相控阵和破坏性试验,验证了此类显示信号为不完全再结晶的奥氏体硬化晶粒造成的冶金显示,不影响耐压壳焊缝的质量,并总结了核电厂核岛设备超声疑似缺陷信号分析验证的方法。Abstract: The control rod drive mechanism (CRDM) pressure housing in nuclear power plants is subjected to high temperature, high pressure and high radiation. The pressure housing welds is prone to crack defects, which is the focus of the in-service inspection during the overhaul. In view of the suspected defects found by Ultrasonic inspection in the pre-service inspection, supplement nondestructive test and destructive test were implemented. The results proved that the indications were metallurgical indications caused by the austenitic hardened grain with incomplete recrystallization, which is without effect on the quality of the welds. The methods of signal analysis for suspected defects were summarized.
-
表 1 超声检查工艺
Table 1. Ultrasonic Inspection Process
序号 探头类型 频率/MHz 角度 楔块形状 检查方向 1 双晶纵波 2 0° AOD147 轴向Y+/Y− 2 双晶纵波 2 45° COD147 周向X+/X− 3 双晶纵波 2 33° COD147 周向X+/X− 4 双晶纵波 2 45° AOD147 轴向Y+/Y− 5 双晶纵波 3 60° AOD147 轴向Y+/Y− AOD147和COD147分别表示沿轴线和周向外径为147 mm弧面的楔块 表 2 超声检查结果
Table 2. Ultrasonic Results
缺陷
编号最大波幅/dB XMax YMax
/mmZMax
/mm缺陷长度/mm 1 DAC−5.0① 351° 27 14.9 14 2 DAC−2.0 93° 24 14.7 23 3 DAC−2.0 191° 24 16.0 23 4 DAC−8.0 118° 27 13.5 5 5 DAC−6.0 287° 9 14.4 20 6 DAC−6.0 232° 27 15.1 5 注:①DAC表示基准距离波幅曲线,DAC−5.0表示缺陷最大波幅比基准波幅曲线低5 dB,其余类推 表 3 体积性显示允许长度
Table 3. Maximum Permitted Length of Volumetric Defects
缺陷反射波最大波幅Hd与标准
反射体波幅Hr的比较值单个缺陷或密集缺陷
最大允许长度/mm(3/2)Hr<Hd(+3.5 dB<Hd/Hr) 不允许 Hr<Hd≤(3/2)Hr(+0 dB<Hd/Hr≤+3.5 dB) 20 (3/4)Hr<Hd≤Hr(−2.5 dB<Hd/Hr≤+0 dB) 30 (1/2)Hr<Hd≤(3/4)Hr
(−6.0 dB<Hd/Hr≤−2.5 dB)60 表 4 无损检测结果
Table 4. Nondestructive Test Results
检查类型 检查项目 检查结果 检查时机 制造阶段 目视 无缺陷 整个制造阶段多
次检查渗透 无缺陷 射线 无可记录显示 最终机加工前 超声 无可记录显示 原材料检查 役前检查
(补充试验)目视 无缺陷 役前检查内部棘
爪组件拆除后射线 无可记录显示 手动超声 6处可记录显示底波降低量约16% 自动超声 手动相控阵 6处可记录显示 -
[1] 兰银辉,孙广,尤磊,等. CPR1000、AP1000和EPR控制棒驱动机构及材料差异分析[J]. 热处理技术与装备,2013, 34(4): 35-40. doi: 10.3969/j.issn.1673-4971.2013.04.010 [2] 周红,肖志,陶书生,等. 运行核电厂控制棒组件及其驱动机构异常事件的经验反馈[J]. 核安全,2013(1): 19-22, 35. doi: 10.3969/j.issn.1672-5360.2013.01.005 [3] 谢航,张益成,周礼峰,等. 奥氏体不锈钢管道环焊缝的超声相控阵检测[J]. 无损检测,2017, 39(3): 23-25, 29. doi: 10.11973/wsjc201703006 [4] 郑晖, 林树青. 超声检测[M]. 北京: 中国劳动社会保障出版社, 2008: 76-77.