Dynamic Characteristics Analysis and Steady-State Operation Scheme Design of Gas-Cooled Microreactor
-
摘要: 气冷微堆是一个高度集成的系统,所涉及的设备是高度耦合和相互约束的。文章通过理论推导,建立了5 MW气冷微堆的动态仿真模型,并分析了系统的动态特性,在此基础上提出了气冷微堆稳态运行方案设计方法。模型稳态计算结果与设计值的相对误差小于1%,瞬态计算结果与实验结果趋势一致,流量最大误差小于0.53 kg/s,压力最大误差小于0.027 MPa。稳态运行方案为:在50%FP~100%FP(FP为满负荷)负荷水平,随负荷的减小,反应堆出口氦气温度和转子转速保持不变;在0%FP~50%FP负荷水平,随负荷的减小,反应堆出口氦气温度和转速线性减小;在0%FP ~100%FP负荷水平,预冷器和间冷器出口氦气温度不变。所提出的稳态运行方案保证了气冷微堆在大范围变工况时安全、稳定和高效地运行。Abstract: The gas-cooled microreactor is a highly integrated system, in which the equipment is highly coupled and mutually constrained. The dynamic simulation model of a 5 MW gas-cooled microreactor is established through theoretical derivation, and the dynamic characteristics of the system are analyzed. On this basis, the steady-state operation scheme design method of the gas-cooled microreactor is proposed. Compared with the design value, the relative error of steady-state calculation results is less than 1%. The transient calculation results of the model are consistent with the experimental results. The maximum error of flow is less than 0.53 kg/s, and the maximum error of pressure is less than 0.027 MPa. The steady-state operation scheme is as follows: at the load level of 50%FP~100%FP (full power), the helium temperature at the reactor outlet and the rotor speed remain unchanged as the load decreases; at the load level of 0%FP~50%FP, the reactor outlet helium temperature and rotor speed linearly decrease with the decrease of the load; the helium temperature at the outlet of precooler and intercooler is constant at 0%FP~100%FP load level. The proposed steady-state operation scheme ensures the safe, stable and efficient operation of the gas-cooled microreactor under a wide range of variable operating conditions.
-
表 1 气冷微堆模型稳态计算结果与设计值对比
Table 1. Comparison between Steady-state Calculation Results of Gas-Cooled Micro-Reactor Model and Design Values
参数 设计值 计算值 相对误差/% 核反应堆功率/MW 5 5 0 反应堆出口氦气温度/℃ 750 750.1 0.1 反应堆出口氦气流量/(kg·s−1) 3.66 3.69 0.8 高压压气机出口氦气压力/MPa 1.73 1.72 0.6 转子转速/(r·min−1) 21600 21600 0 电功率/MW 1.81 1.81 0 预/间冷器出口氦气温度/℃ 35 35 0 -
[1] 能源局,科技部. 《“十四五”能源领域科技创新规划》国能发科技〔2021〕58号[EB/OL]. 能源局网站. (2021-11-29)[2023-03-12]. https://dpd.bzu.edu.cn/2022/0913/c12825a236385/page.htm. [2] TESTONI R, BERSANO A, SEGANTIN S. Review of nuclear microreactors: status, potentialities and challenges[J]. Progress in Nuclear Energy, 2021, 138: 103822. doi: 10.1016/j.pnucene.2021.103822 [3] DONG Z, PAN Y F, ZHANG Z Y, et al. Dynamical modeling and simulation of the six-modular high temperature gas-cooled reactor plant HTR-PM600[J]. Energy, 2018, 155: 971-991. doi: 10.1016/j.energy.2018.05.056 [4] QIU L L, WEI X Y, SUN P W, et al. Study on the dynamic modeling of the micro-high temperature gas cooled reactor for control system design[C]//28th International Conference on Nuclear Engineering. ICONE, 2021 . [5] QIU L L, LIAO S Y, FAN S, et al. Dynamic modelling and control system design of micro-high-temperature gas-cooled reactor with helium Brayton cycle[J]. Energy, 2023, 278: 128030. doi: 10.1016/j.energy.2023.128030 [6] LIAO S Y, QIU L L, BI X L, et al. Dynamic modeling and characteristic analysis of helium Brayton cycle system[C]//29th International Conference on Nuclear Engineering. ICONE, 2022. [7] BAMMERT K, JOHANNING J, WEIDNER E. Instrumentierung und verfahren zur messung des dynamischen verhaltens der heliumturbinenanlage oberhausen[J]. Atomkernenergie/Kerntechnik, 1983, 4(43): 225-239. [8] BENTIVOGLIO F, TAUVERON N, GEFFRAYE G, et al. Validation of the CATHARE2 code against experimental data from Brayton-cycle plants[J]. Nuclear Engineering and Design, 2008, 238(11): 3145-3159. doi: 10.1016/j.nucengdes.2007.12.026