LI Xingqiang, WANG Yinli, XIAO Yu, XUE Bin. Analysis and Solution of Spike Current of Intermediate Range for Nuclear Instrumentation System[J]. Nuclear Power Engineering, 2015, 36(1): 104-107. doi: 10.13832/j.jnpe.2015.01.0104
Citation:
LI Xingqiang, WANG Yinli, XIAO Yu, XUE Bin. Analysis and Solution of Spike Current of Intermediate Range for Nuclear Instrumentation System[J]. Nuclear Power Engineering, 2015, 36(1): 104-107. doi: 10.13832/j.jnpe.2015.01.0104
LI Xingqiang, WANG Yinli, XIAO Yu, XUE Bin. Analysis and Solution of Spike Current of Intermediate Range for Nuclear Instrumentation System[J]. Nuclear Power Engineering, 2015, 36(1): 104-107. doi: 10.13832/j.jnpe.2015.01.0104
Citation:
LI Xingqiang, WANG Yinli, XIAO Yu, XUE Bin. Analysis and Solution of Spike Current of Intermediate Range for Nuclear Instrumentation System[J]. Nuclear Power Engineering, 2015, 36(1): 104-107. doi: 10.13832/j.jnpe.2015.01.0104
During the initial start-up of HYH NPP unit 1, spike currents occurred in intermediate range channel of RPN system and reactor trip was triggered. After analyzing the operation principle of intermediate range channel and site inspection, and doing simulating test, the root cause was fixed on the bug of range switching of intermediate range channel. Then a solution based on parameters optimizing was made and executed on site.