He Gening, He Jingsong, Li Donghui, Wu Ge, Huo Meng. Flow Analysis and Structure Optimization of Electric Heating Tank of Steam Generator Secondary Side Pre-Service Hydrostatic Test System[J]. Nuclear Power Engineering, 2015, 36(S2): 46-49. doi: 10.13832/j.jnpe.2015.S2.0046
Citation: He Gening, He Jingsong, Li Donghui, Wu Ge, Huo Meng. Flow Analysis and Structure Optimization of Electric Heating Tank of Steam Generator Secondary Side Pre-Service Hydrostatic Test System[J]. Nuclear Power Engineering, 2015, 36(S2): 46-49. doi: 10.13832/j.jnpe.2015.S2.0046

Flow Analysis and Structure Optimization of Electric Heating Tank of Steam Generator Secondary Side Pre-Service Hydrostatic Test System

doi: 10.13832/j.jnpe.2015.S2.0046
  • Received Date: 2015-11-04
  • Rev Recd Date: 2015-11-14
  • Available Online: 2025-02-15
  • This paper conducts the fluid solid coupled three-dimensional numerical simulation on the electric heating tank,using the computational fluid dynamics(CFD) method. A new supporting plate structure is proposed by optimizing the design. The new structure can provide reliable support for the electric heater, and the highest surface temperature of the electric heater decreased significantly(reduce about 100℃). The new structure can effectively prevent the liquid vaporization caused by local high temperature of the electric heater surface.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (25) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return