Advance Search
Volume 37 Issue 2
Feb.  2025
Turn off MathJax
Article Contents
Huang Wen, Tan Tiancai, Ma Janzhong. Stress Calculated by Two Models of Large Storage Tank[J]. Nuclear Power Engineering, 2016, 37(2): 127-128. doi: 10.13832/j.jnpe.2016.02.0127
Citation: Huang Wen, Tan Tiancai, Ma Janzhong. Stress Calculated by Two Models of Large Storage Tank[J]. Nuclear Power Engineering, 2016, 37(2): 127-128. doi: 10.13832/j.jnpe.2016.02.0127

Stress Calculated by Two Models of Large Storage Tank

doi: 10.13832/j.jnpe.2016.02.0127
  • Received Date: 2015-05-19
  • Rev Recd Date: 2015-12-01
  • Available Online: 2025-02-15
  • Two methods for mutual verification calculation of simplified model and fluid solid coupling model are used in the stress analysis of the large storage tank. The calculation for pulsed liquid quality M0, the height of gravity of pulsed liquid H0, the height of gravity of liquid convection H1, and the equivalent stiffness k1 of spring simulating slosh frequency of liquid convection is based on HOUSNER theory and as the input parameters of finite element model. FLUID80 elements are used in the fluid solid coupling model to model the fluid and SHELL181 elements to model the storage tank. Fluid solid coupling model considering the structure damp is used to calculate the response of the tank under seismic time history.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (26) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return