Advance Search
Volume 40 Issue 6
Dec.  2019
Turn off MathJax
Article Contents
Xing Limiao, Zhan Li, Xie Xu, Wu Xiaofei, Xu Shijie, Xu Changzhe, Ma Nan. Design Improvement of DBA Environmental Test Facility for Generation Ⅲ Nuclear Power Plants[J]. Nuclear Power Engineering, 2019, 40(6): 95-99. doi: 10.13832/j.jnpe.2019.06.0095
Citation: Xing Limiao, Zhan Li, Xie Xu, Wu Xiaofei, Xu Shijie, Xu Changzhe, Ma Nan. Design Improvement of DBA Environmental Test Facility for Generation Ⅲ Nuclear Power Plants[J]. Nuclear Power Engineering, 2019, 40(6): 95-99. doi: 10.13832/j.jnpe.2019.06.0095

Design Improvement of DBA Environmental Test Facility for Generation Ⅲ Nuclear Power Plants

doi: 10.13832/j.jnpe.2019.06.0095
  • Publish Date: 2019-12-15
  • The environmental qualification test facility of Nuclear Power Institute of China, cannot meet the requirement of the environmental test of loss of coolant accident (LOCA) in the third generation NPPs, for the issues such as the inadequate capability of temperature rising and the uneven temperature distribution in the test chamber during the thermal shock. To solve these issues, the RELAP5 code was used for the numerical analysis for the design improvement of the test facility. Based on results of the numerical analysis, the facility was improved. The test results from the improved facility demonstrated that the capability of temperature rising in the test chamber during the thermal shock and the uniformity of the temperature distribution was largely improved. The new facility meets the requirements of design base accident (DBA) environmental test for the third generation NPPs.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (752) PDF downloads(2) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return