By building the RPV model, the phase array (PA) ultrasonic detection technology was developed to replace the conventional ultrasonic detection technology, and then the detection and quantitative capability of the two detection technologies were compared and evaluated. The verification tests show that the detection and quantification capability of PA ultrasonic detection technology meets the standard requirement. At the same time, it can greatly shorten the inspection time and have considerable economic benefits.