Development and Verification of HLPS Software for LOCA Hydraulics Load Analysis

doi: 10.13832/j.jnpe.2021.04.0159
  • Received Date: 2020-05-16
  • Rev Recd Date: 2021-01-11
  • Publish Date: 2021-08-15
  • In order to analyze the hydrodynamic loading characteristics caused by coolant jetting and pressure relief wave propagating in the reactor primary system of the nuclear power plant during a hypothetical fracture of the reactor primary system, HLPS, a software to calculate the hydraulic load in the loss of coolant accident (LOCA) in PWR primary circuit, is developed on self-reliance using C++ programming language. Taking M310 reactors coolant as the object, the results of HLPS software are compared with engineering data. The results show that the calculated results of HLPS software are in good agreement with engineering data, at the same time, HLPS adopts implicit solution and higher convergence standard, and the result is more accurate. It can be used for the analysis of the primary circuit system coolant loss accident.

     

  • loading
  • [1]
    余红星,黄代顺. 秦山核电二期工程设计基准事故水力学载荷分析[J]. 核动力工程,2003, 24(S2): 102-105.
    [2]
    余红星. 蒸汽发生器隔板和传热管束的水力学载荷分析[J]. 核动力工程,1999, 20(4): 348-351.
    [3]
    MOODY F J. Maximum flow rate of a single component, two-phase mixture[J]. Journal of Heat Transfer, 1965, 87(1): 134-141. doi: 10.1115/1.3689029
    [4]
    HENRY E. Calculation techniques for two phase critical flow[Z]. Illinois: Argonne National Laboratory, 1981.
    [5]
    唐琼辉,周瑞,吴应喜,等. 失水事故下一回路水动力载荷分析[J]. 核科学与工程,2014, 34(4): 462-468, 474.
    [6]
    American Nuclear Society Standard Committee. Design basis for protection of light water nuclear power plants against the effects of postulated pipe rupture: ANSI/ANS-58.2—1988[S]. USA: American Nuclear Society, 1988: 1-7