Advance Search
Volume 44 Issue 3
Jun.  2023
Turn off MathJax
Article Contents
Chen Jing, Lu Yanzhen, Jiang Hao, Lin Weiqing, Xu Yong. Anomaly Detection of Core Self-Powered Neutron Detector Based on Twin Model[J]. Nuclear Power Engineering, 2023, 44(3): 210-216. doi: 10.13832/j.jnpe.2023.03.0210
Citation: Chen Jing, Lu Yanzhen, Jiang Hao, Lin Weiqing, Xu Yong. Anomaly Detection of Core Self-Powered Neutron Detector Based on Twin Model[J]. Nuclear Power Engineering, 2023, 44(3): 210-216. doi: 10.13832/j.jnpe.2023.03.0210

Anomaly Detection of Core Self-Powered Neutron Detector Based on Twin Model

doi: 10.13832/j.jnpe.2023.03.0210
  • Received Date: 2022-06-23
  • Rev Recd Date: 2023-03-23
  • Publish Date: 2023-06-15
  • Self-powered neutron detector (SPND) is an important nuclear sensing device in the core, whose health status affects the safe operation of the reactor directly. Considering the measurement correlation between SPNDs at different positions in the reactor, a twin model-based anomaly detection method for SPND signals in the core was proposed in this paper. The characteristics of measurement signals of neighboring SPNDs were extracted by the Random Forest Regression (RFR) algorithm based on the historical operation data of SPND, and a twin model was built for SPNDs which outputs the same as its physical entity. Twin model and entity sensing coexisted. The residual error between the actual observation value of SPND and the twin model estimation value was calculated to serve as the anomaly detection criterion, which realized the identification and location of single-point and multi-point SPND anomalies. The experiments show that the prediction error of the twin model proposed in this paper attains the order of 1×10−10, which has a very high output consistency. The identification accuracy of anomaly detection can reach over 99% under various abnormal states of SPND signals, and the single-point and multi-point abnormal SPND can be accurately identified, which has a high reference value for improving the reliability and safety of the state monitoring of neutron flux measurement system in the core.

     

  • loading
  • [1]
    李树成,胡铸萱. CAP 1400核电厂堆芯钒自给能中子探测器设计与验证[J]. 核电子学与探测技术,2018, 38(5): 699-702.
    [2]
    黄有骏,李文平,杨戴博,等. 华龙一号堆芯中子注量率测量系统自给能中子探测器关键参数研究[J]. 核动力工程,2020, 41(S2): 45-49. doi: 10.13832/j.jnpe.2020.S2.0045
    [3]
    YELLAPU V S, TIWARI A P, DEGWEKER S B. Application of data reconciliation for fault detection and isolation of in-core self-powered neutron detectors using iterative principal component test[J]. Progress in Nuclear Energy, 2017, 100: 326-343. doi: 10.1016/j.pnucene.2017.04.017
    [4]
    GAUTAM S, TAMBOLI P K, ROY K, et al. Sensors incipient fault detection and isolation of nuclear power plant using extended Kalman filter and Kullback–Leibler divergence[J]. ISA Transactions, 2019, 92: 180-190. doi: 10.1016/j.isatra.2019.02.011
    [5]
    YELLAPU V S, ZHANG W D, VAJPAYEE V, et al. A multiscale data reconciliation approach for sensor fault detection[J]. Progress in Nuclear Energy, 2021, 135: 103707. doi: 10.1016/j.pnucene.2021.103707
    [6]
    CHATTERJEE S, SURWASE S K, BHUSHAN M, et al. Cluster statistics based normalization for online fault diagnosis of self-powered neutron detectors[C]//2017 International Conference on Information, Communication, Instrumentation and Control (ICICIC). Indore: IEEE, 2017: 1-6.
    [7]
    ZAREI M. A Kalman filtering of the Self-Powered Neutron Detector current to determine excess reactivity[J]. Radiation Physics and Chemistry, 2021, 188: 109602. doi: 10.1016/j.radphyschem.2021.109602
    [8]
    VOLODIN V S, TOLOKONSKII A O. Concept of instrumentation of digital twins of nuclear power plants units as observers for digital NPP I&C system[C]//8th International Conference on Mathematical Modeling in Physical Science. Bratislava: IOP, 2019: 012083.
    [9]
    KOCHUNAS B, HUAN X. Digital twin concepts with uncertainty for nuclear power applications[J]. Energies, 2021, 14(14): 4235. doi: 10.3390/en14144235
    [10]
    NGUYEN T N, PONCIROLI R, BRUCK P, et al. A digital twin approach to system-level fault detection and diagnosis for improved equipment health monitoring[J]. Annals of Nuclear Energy, 2022, 170: 109002. doi: 10.1016/j.anucene.2022.109002
    [11]
    胡梦岩,孔繁丽,余大利,等. 数字孪生在先进核能领域中的关键技术与应用前瞻[J]. 电网技术,2021, 45(7): 2514-2522. doi: 10.13335/j.1000-3673.pst.2021.0335
    [12]
    AKS A,JSK B,LV B. Digital twin in energy industry: Proposed robust digital twin for power plant and other complex capital-intensive large engineering systems[J]. Energy Reports, 2022, 8: 3704-3726. doi: 10.1016/j.egyr.2022.02.305
    [13]
    LIN L Y, ATHE P, ROUXELIN P, et al. Digital-twin-based improvements to diagnosis, prognosis, strategy assessment, and discrepancy checking in a nearly autonomous management and control system[J]. Annals of Nuclear Energy, 2022, 166: 108715. doi: 10.1016/j.anucene.2021.108715
    [14]
    刘皓璐,邵建伟,王雪,等. 基于数字孪生的配电自动化终端设备状态评价与故障预判[J]. 电网技术,2022, 46(4): 1605-1613. doi: 10.13335/j.1000-3673.pst.2021.0661
    [15]
    张西宁,张雯雯,周融通,等. 采用单类随机森林的异常检测方法及应用[J]. 西安交通大学学报,2020, 54(2): 1-8,157.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(6)  / Tables(2)

    Article Metrics

    Article views (250) PDF downloads(42) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return