Li Jun, Wang Shuqiang. Analysis and Optimization of Primary Circuit Pressure Drop Caused by RCP Inching for the First Time after Refueling Overhaul in Nuclear Power Plant[J]. Nuclear Power Engineering, 2024, 45(6): 226-231. doi: 10.13832/j.jnpe.2024.06.0226
Citation: Li Jun, Wang Shuqiang. Analysis and Optimization of Primary Circuit Pressure Drop Caused by RCP Inching for the First Time after Refueling Overhaul in Nuclear Power Plant[J]. Nuclear Power Engineering, 2024, 45(6): 226-231. doi: 10.13832/j.jnpe.2024.06.0226

Analysis and Optimization of Primary Circuit Pressure Drop Caused by RCP Inching for the First Time after Refueling Overhaul in Nuclear Power Plant

doi: 10.13832/j.jnpe.2024.06.0226
  • Received Date: 2023-12-25
  • Rev Recd Date: 2024-06-24
  • Publish Date: 2024-12-17
  • After the refueling overhaul of pressurized water reactor nuclear power plant, the first inching of the reactor coolant pump (RCP) will cause a significant decrease in the primary circuit pressure. If the pressure drops below the operating range specified in the technical specifications, there is a risk of RCP cavitation and shaft seal damage, which threatens the safety of the core. In this paper, the mechanism that the primary pressure drops sharply when the RCP is inched for the first time after refueling overhaul in nuclear power plant is analyzed theoretically, and three optimization methods are put forward to control the pressure drop, including determining the timing and principles for shutting down the RCP, determining the starting sequence of the RCP, setting the initial pressure of the primary circuit and using the primary pressure regulating valve to automatically respond quickly. The practical results show that the optimized and improved control method for the inching of RCP can reduce the pressure drop in the primary circuit by 0.2 MPa. The optimized and improved control method of inching RCP established in this study can reduce the risk of cavitation and shaft seal damage of RCP.

     

  • loading
  • [1]
    广东核电培训中心. 900 MW压水堆核电站系统与设备[M]. 北京: 中国原子能出版社,2005: 90-101.
    [2]
    陈鹏,王志华,赵洋. 主泵首次启动风险分析与应对措施[J]. 科技传播,2016,8(8): 170,172.
    [3]
    谭海波,赵鑫,杨森垓,等. 压水堆核电机组一回路抽真空排气技术[J]. 核动力工程,2014, 35(3): 88-91.
    [4]
    JU C Y. Ling ao nuclear power station units 1 & 2 final safety analysis report[Z]. China, Guangdong:China Ling Ao Nuclear Power Company Ltd. , 2002.
    [5]
    张明乾,刘昱,李承亮. 浅谈压水堆核电站AP1000屏蔽式电动主泵[J]. 水泵技术,2008(4): 1-5.
    [6]
    钟云,周文霞. 一种适用范围更广的核主泵惰转计算方法[J]. 核动力工程,2023, 44(6): 231-236.
    [7]
    焦喆,蔡龙,张丽平,等. 考虑管路中冷却剂动能的反应堆冷却剂泵惰转计算模型[J]. 核动力工程,2022, 43(1): 48-51.
    [8]
    苏宋洲,王鹏飞,许忠斌,等. 核主泵启动过程压力脉动和径向力研究[J]. 核动力工程,2017, 38(3): 110-114.