Comparing with RCCM code Ver.2000,some changes for pressure-temperature(P-T) limit curve calculation in the Ver.2007 are introduced,and two P-T limit curve calculation procedures are proposed based on the Ver.2007.In the numerical example,the P-T limit curves are given by the RCCM code Ver.2000 and Ver.2007,respectively.Furthermore,the effect of some parameters,such as the cooling rate and the cladding,on the P-T limit curves,is studied.