SHANG Xian-you, SHI Jian-zhong, WANG Xue-hua, HU You-qing, SHI Ying. Study on Chain Relationship between Condenser and Vacuum Isolation Valve[J]. Nuclear Power Engineering, 2013, 34(4): 140-142.
Citation: SHANG Xian-you, SHI Jian-zhong, WANG Xue-hua, HU You-qing, SHI Ying. Study on Chain Relationship between Condenser and Vacuum Isolation Valve[J]. Nuclear Power Engineering, 2013, 34(4): 140-142.

Study on Chain Relationship between Condenser and Vacuum Isolation Valve

  • Received Date: 2012-02-06
  • Rev Recd Date: 2013-03-11
  • Available Online: 2025-03-08
  • In the condenser unilateral isolation conditions,the corresponding vacuum isolation valve should be shut down at the same time,and in any case,it is not recommended to open the valve,otherwise some consequences would occur,such as the increasing of non-condensable gas of the condenser,and degrading of vacuum pump performance and condenser performance.This paper makes a comparison of unilateral isolated condition and the normal operation condition,and analyzes the condenser leakage,non-condensing gas accumulation trends,vacuum pump performance,and the performance of the condenser.

     