Preliminary Study on the Effect of Spray Model on Hydrogen Explosion
-
摘要: 采用MELCOR程序比较了大亚湾核电站在全厂断电事故下,恢复供电后不同喷淋模式对事故进 程的影响。结果显示,采用较短的喷淋持续时间和适宜的喷淋投入时间,能较明显地避免氢燃或降低氢燃的 强度,从而延迟安全壳内压力到达限值的时间。Abstract: The effects of different spray models on the accident progress after the power recovery at blackout accident in Daya Bay Nuclear Power Plant were compared by MELCOR code. The result showed that the hydrogen combustion can be avoided or mitigated substantially by shorter spray duration and proper start time to activate the spray, and thus the time for the pressure in the containment reaching the limit can be retarded.
-
Key words:
- Severe accident /
- Blackout /
- Spray model /
- Hydrogen combustion
-
计量
- 文章访问数: 4
- HTML全文浏览量: 1
- PDF下载量: 0
- 被引次数: 0