Analysis of Uncontrolled Boron Dilution Accident at Ling'ao Nuclear Power Station
-
摘要: 在岭澳核电站混合堆芯及提高富集度论证项目中的反应性事故中,硼稀释事故分析占据着重要的地位。因为硼稀释事故分析的结论中要对冷停堆和热停堆下的控制棒棒位进行定义,其中热停堆下的控制棒棒位又是次临界下提棒事故分析的前提,而且在次临界提棒事故裕量不够时,可以通过硼稀释事故分析来对热停堆标准工况下的棒位进行一定的调整以提高次临界提棒事故裕量。对混合堆芯论证项目中的硼稀释事故分析的方法、结论进行了说明。Abstract: Boron Dilution Accident(UBDA) analysis plays a significant role in the reactivity accidents during the justification of Ling’ao Mixed Core and Increased Enrichment project.As the conclusion of the accident analysis will define the standard control rod position at both cold and hot shutdown conditions,of which the control rod position of hot shutdown serves as the premise of Rod Withdrawal from Subcriticality(RWS) accident analysis,the rod position of standard hot shutdown can be adjusted through UBDA analysis in an effort to provide the margin for RWS accident analysis.A detailed analysis method and conclusion of BDA at Ling’ao Nuclear Power Station are described in this paper.
-
Key words:
- Boron dilution /
- Reactivity /
- Ling'ao Nuclear Power Station
-
计量
- 文章访问数: 3
- HTML全文浏览量: 1
- PDF下载量: 0
- 被引次数: 0