Abstract:
Considering the shortcomings of traditional fixed threshold set as alarm threshold for fuel cladding failure monitoring, this paper puts forward the concept of floating alarm threshold and carries on a preliminary study on floating alarm threshold setting, based on mathematical statistical and probabilistic analysis method. The study shows that during fuel cladding failure monitoring, floating alarm threshold can monitor the condition of fuel cladding failure in a more accurate way and at a higher speed and alarm in time.