摘要: 介绍了压水堆核电站反应堆硼和除盐水补给系统(REA)硼酸箱容积的设计准则,以及技术规范对REA硼酸箱容积的限制要求。在比较分析大亚湾核电站18个月换料改造和岭澳一期核电站1/4换料堆芯改造对REA硼酸箱容积论证的基础上,预评估将来提高18个月换料燃料富集度到4.95%时,现有REA硼酸箱容积和硼酸浓度的缺额。为满足设计准则对REA硼酸箱容积的技术要求,建议在新电站设计中适当提高REA硼酸箱容积或者提高硼酸浓度。Abstract: This paper discussed the design rules of the boric acid tank volume of reactor boron and water makeup system(REA) in PWR nuclear plant and the limit requirements of the tank volume in the operation technical specification. Based on the comparison and analysis of the arguments of Daya Bay nuclear plant 18 months refueling modification and Ling’ao nuclear plant 1/4 refueling modification, the paper pre-assessed and calculated the lack of the REA boric acid tank volume as the fuel enrichment upgraded to 4.95% in the future, and proposed the suggestion of increasing the volume or boric acid concentration of the REA system in new nuclear plant design in order to meet the operation technical specification requirements.
-