Migration and Control of Activated Corrosion Products in Primary Coolant Loop During Reactor Shutdown Oxygenation Operation
-
摘要: 核电站主回路中腐蚀产物的氧化净化是核电站大修的源项控制中最重要的一环。本文综合分析氧化净化过程中pH值、H2O2和溶解氢浓度对主回路活化腐蚀产物迁移的影响,结合大亚湾核电站的实践经验,提出了低pH值、低H2和集中引入适量氧的控制手段。Abstract: The oxidation and purification of the primary coolant loop is of great importance in control-ling the dose rate during the outage.In this paper,the effects of pH value,H2O2 and H2 concentration on the migration of activated corrosion products were discussed theoretically.A new method for the shutdown oxy-genation operation,characterized by low pH,low H2 and introducing oxygen densely at suitable amount,was proposed based on the operation experience of Daya Bay nuclear power station.
-
Key words:
- Oxygenation operation /
- pH /
- H2O2 /
- H2 /
- Activated corrosion products /
- Migration
-
计量
- 文章访问数: 6
- HTML全文浏览量: 2
- PDF下载量: 0
- 被引次数: 0