Evaluation of RELAP5 Code by Experiments of Integral Test Facility
-
摘要: 针对一体化自然循环试验装置OSU-MASLWR开展的实验,采用系统分析程序RELAP5/MOD3.3进行分析计算。失水事故瞬态计算结果表明,堆芯有足够的冷却,加热元件在整个瞬态过程中温度不断降低。安全壳内出现热分层现象,通过安全壳壁从安全壳到周围水池的热传递速率足以除去堆芯的衰变热。与试验结果相比,程序基本预测了整个瞬态过程中各参数的变化情况。Abstract: With reference to the parameters of integral natural circulation test facility OSU-MASLWR, the system analysis code RELAP5/MOD3.3 was applied to investigate the thermal-hydraulic characteristics. Transient safety studies were done for loss-of-coolant accidents within the containment. The results show that the reactor core can be provided with a stable cooling source adequate to remove decay heat without significant cladding heatup under all scenarios. Further, the heat rejected through the containment wall to the surrounding pool of water will be greater than the amount of the decay heat produced by the reactor core. The thermal stratification phenomenon occurs in the containment. Comparison of calculated results and experiment data shows that the phenomena of interest are predicted by the code.
-
Key words:
- Integral test facility /
- Passive safety system /
- Natural circulation /
- LOCA
-