摘要: 燃料组件抓具驱动回路是核电厂装卸料机的核心部分,其可靠性对于燃料组件装卸工作的安全稳定进行具有重要意义。秦山第二核电厂1#、2#机组装卸料机自投运以来发生了多次抓具无法脱扣的故障,对反应堆大修装卸料工作产生了一定的影响。以装卸料机燃料组件抓具驱动回路为研究对象,结合抓具无法脱扣的故障现象,对驱动气缸、气路系统和抓具本体等关键部件出现的缺陷进行原因分析,介绍了抓具无法脱扣的故障排查方法,提出了针对性的应对措施。Abstract: Fuel assembly gripper driving circuit is a key part of the refueling machine. Its reliability has great significance for safety and stability of refueling operation. A number of tripping faults have occurred since the operation of the refueling machine No.1 and No.2 of Qinshan nuclear power plant II, and it has a certain impact on the refueling operation. With gripper driving circuit as the research object, considering the fault phenomenon and the maintenance experiences, the reasons of key components defect were analyzed in detail, the troubleshooting methods and solutions were summarized, and the measures to solve the problem was provided.
-