Advance Search
Volume 35 Issue 5
Feb.  2025
Turn off MathJax
Article Contents
Hu Xiaoying. Study on Seismic Margin of Protection System Cabinet for Nuclear Power Plants[J]. Nuclear Power Engineering, 2014, 35(5): 28-30. doi: 10.13832/j.jnpe.2014.05.0028
Citation: Hu Xiaoying. Study on Seismic Margin of Protection System Cabinet for Nuclear Power Plants[J]. Nuclear Power Engineering, 2014, 35(5): 28-30. doi: 10.13832/j.jnpe.2014.05.0028

Study on Seismic Margin of Protection System Cabinet for Nuclear Power Plants

doi: 10.13832/j.jnpe.2014.05.0028
  • Received Date: 2013-08-20
  • Rev Recd Date: 2014-04-22
  • Available Online: 2025-02-15
  • This paper takes the protection system cabinet in Qinshan Nuclear Power Plant as an example, based on the existing required response spectrum and test response spectrum of functional component inside cabinet and cabinet frame and enclosure, an easy CDFM(Conservative Deterministic Failure Margin) analysis method mentioned in EPRI NP-6041-SL technical report is adopted to calculate the seismic margin earthquake scale factor through parameters’ selection such as clipping factor, effective cabinet amplification factor, knockdown factor and so on to find seismic margin of existing protection system cabinet.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (57) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return