  • Modal analysis of the containment spray pump is carried out by using ANSYS program, and structural natural frequencies and modes of vibration can be obtained. After that, the dynamic characteristic test is performed for the containment spray pump. The comparison between modal analysis results and test results show that they agree well. It verifies the validity of the model and lays the foundation for the structural integrity analysis of the containment spray pump.

     