Wang Zhenying, Sun Chen, Wu Bei. Estimation of Measurement Uncertainties for Subcooling Margin of Coolant at Core Outlet in CPR1000 NPPs[J]. Nuclear Power Engineering, 2015, 36(2): 24-27. doi: 10.13832/j.jnpe.2015.02.0024
Citation: Wang Zhenying, Sun Chen, Wu Bei. Estimation of Measurement Uncertainties for Subcooling Margin of Coolant at Core Outlet in CPR1000 NPPs[J]. Nuclear Power Engineering, 2015, 36(2): 24-27. doi: 10.13832/j.jnpe.2015.02.0024

Estimation of Measurement Uncertainties for Subcooling Margin of Coolant at Core Outlet in CPR1000 NPPs

doi: 10.13832/j.jnpe.2015.02.0024
  • Received Date: 2014-03-27
  • Rev Recd Date: 2014-06-25
  • Available Online: 2025-02-15
  • The core cooling and monitoring system(CCMS) is installed in CPR1000 nuclear power plants to measure the subcooling margin of the coolant at the core outlet. Every error origin in the process of the measurement was investigated in this paper. The uncertainties of the subcooling margin measurement was estimated in saturation condition for the case of the distribution of the coolant temperature at the core outlet is heterogeneous or homogeneous, and the curves of uncertainty interval boundaries changing with primary pressure were obtained, based on which the method for determination of the error(ε) curve of the subcooling margin measurement which is used in CCMS to diagnose the cooling state of the core is developed. The acquired results have been practically implemented in CPR1000 nuclear power plants.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (77) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return