Yu Hong, CHeng Shisi. Discussion about Relation between “A” Type EOP for PWR and Emergency Classification Level[J]. Nuclear Power Engineering, 2015, 36(2): 84-88. doi: 10.13832/j.jnpe.2015.02.0084
Citation:
Yu Hong, CHeng Shisi. Discussion about Relation between “A” Type EOP for PWR and Emergency Classification Level[J]. Nuclear Power Engineering, 2015, 36(2): 84-88. doi: 10.13832/j.jnpe.2015.02.0084
Yu Hong, CHeng Shisi. Discussion about Relation between “A” Type EOP for PWR and Emergency Classification Level[J]. Nuclear Power Engineering, 2015, 36(2): 84-88. doi: 10.13832/j.jnpe.2015.02.0084
Citation:
Yu Hong, CHeng Shisi. Discussion about Relation between “A” Type EOP for PWR and Emergency Classification Level[J]. Nuclear Power Engineering, 2015, 36(2): 84-88. doi: 10.13832/j.jnpe.2015.02.0084
The EOP for the first reactor of Fangjiashan Nuclear Power Plant is taken as an example in this paper. The indications and the parameters in the EOP are compared with the EAL in NEI 99-01 to discuss which emergency classification level the plant should be into when the "A" type EOP is implemented. Developing the EAL, the indications and the parameters should be taken into account.