Advance Search
Volume 37 Issue 1
Feb.  2025
Turn off MathJax
Article Contents
Rao Yuxian, Yu Lei, Fu Shengwei. Study on Steam Condensation Model of A PRS Heat Exchanger[J]. Nuclear Power Engineering, 2016, 37(1): 34-37. doi: 10.13832/j.jnpe.2016.01.0034
Citation: Rao Yuxian, Yu Lei, Fu Shengwei. Study on Steam Condensation Model of A PRS Heat Exchanger[J]. Nuclear Power Engineering, 2016, 37(1): 34-37. doi: 10.13832/j.jnpe.2016.01.0034

Study on Steam Condensation Model of A PRS Heat Exchanger

doi: 10.13832/j.jnpe.2016.01.0034
  • Received Date: 2015-04-20
  • Rev Recd Date: 2015-08-23
  • Available Online: 2025-02-15
  • Steady-state calculations are performed using RELAP5/MOD3.2 code for a test facility which has the same size as one type of secondary-side passive residual heat removal system. In some conditions there are obvious differences between calculation results and experimental data. Thereby, the steam vertical in-tube condensation models for laminar and turbulent conditions in RELAP5 code are improved by considering the interfacial shear stress between vapor and liquid film and high system pressure, respectively. Steady-state and transient calculations are performed using the improved RELAP5 code for the test facility. The simulation results give a good agreement with the experimental data.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (57) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return