Advance Search
Volume 38 Issue 1
Feb.  2025
Turn off MathJax
Article Contents
Yang Yang. Research of MCR Inleakage Tracer Gas Test of AP1000 Nuclear Power Plant[J]. Nuclear Power Engineering, 2017, 38(1): 131-134. doi: 10.13832/j.jnpe.2017.01.0131
Citation: Yang Yang. Research of MCR Inleakage Tracer Gas Test of AP1000 Nuclear Power Plant[J]. Nuclear Power Engineering, 2017, 38(1): 131-134. doi: 10.13832/j.jnpe.2017.01.0131

Research of MCR Inleakage Tracer Gas Test of AP1000 Nuclear Power Plant

doi: 10.13832/j.jnpe.2017.01.0131
  • Received Date: 2016-03-08
  • Rev Recd Date: 2016-07-22
  • Available Online: 2025-02-09
  • Combining with the sealed design of AP1000 MCR and passive design of MCR ventilation systems,this paper explores the method and theory which is suitable for AP1000 main control room inleakage tracer gas test and anticipates the test results and difficulties.Results show that the constant injection test is the preferred method for AP1000 main control room inleakage tracer gas test.The constant injection test based on mature theories and with strong operability and high precision,can well meet the AP1000 passive design verification requirements.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (69) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return