Advance Search
Volume 38 Issue 2
Feb.  2025
Turn off MathJax
Article Contents
Zhang Lin, Wu Xiaofei, Li Minggang, Rong Xiaohong, Wang Yunsheng. Optimization Research of Elbow Flow Meter Design with Alterable Measurement Range[J]. Nuclear Power Engineering, 2017, 38(2): 145-148. doi: 10.13832/j.jnpe.2017.02.0145
Citation: Zhang Lin, Wu Xiaofei, Li Minggang, Rong Xiaohong, Wang Yunsheng. Optimization Research of Elbow Flow Meter Design with Alterable Measurement Range[J]. Nuclear Power Engineering, 2017, 38(2): 145-148. doi: 10.13832/j.jnpe.2017.02.0145

Optimization Research of Elbow Flow Meter Design with Alterable Measurement Range

doi: 10.13832/j.jnpe.2017.02.0145
  • Received Date: 2016-04-27
  • Rev Recd Date: 2017-01-24
  • Available Online: 2025-02-09
  • In this paper,the design concept of two elbow flowmeters with alterable measurement range is studied by CFX numerical simulation.The results show that:a.changing the pressure taps of the traditional elbow flow meter could not significantly increase the differential pressure under the low flow condition;b.Throttling elements could increase the differential pressure;c.The airfoil could make the differential pressure increase 25%.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (63) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return