Advance Search
Volume 30 Issue 5
Oct.  2009
Turn off MathJax
Article Contents
MO Zheng-yu, WU Chao, LI Hai-feng, LIU Hua, YU Zhong-bin. Analysis of Canned-Motor Pump Jamming Failure in Start Hot Standby Mode[J]. Nuclear Power Engineering, 2009, 30(5): 93-95,108.
Citation: MO Zheng-yu, WU Chao, LI Hai-feng, LIU Hua, YU Zhong-bin. Analysis of Canned-Motor Pump Jamming Failure in Start Hot Standby Mode[J]. Nuclear Power Engineering, 2009, 30(5): 93-95,108.

Analysis of Canned-Motor Pump Jamming Failure in Start Hot Standby Mode

  • Received Date: 2009-04-17
  • Rev Recd Date: 2009-09-10
  • Available Online: 2025-07-28
  • Publish Date: 2009-10-15
  • The reason of a canned-motor pump start failure is deduced in this paper. It is shown that the undersized gap of the lower guide bearing causes the start failure. By the stripping inspection data, the design value of the guide bearing gap, the cumulative departure of manufacturing assembly and the preloading of the bearing liner lead to the undersized gap. The test result shows that the improved canned-motor pump can start up successfully.

     