Advance Search
Volume 29 Issue 6
Dec.  2008
Turn off MathJax
Article Contents
WANG Jian-ping, JIN Wei-ya, WANG Xiu-min, GAO Zeng-liang. Study on Pull-out Force in Tube-and-Shell Heat Exchangers with Finite Element Method[J]. Nuclear Power Engineering, 2008, 29(6): 58-61.
Citation: WANG Jian-ping, JIN Wei-ya, WANG Xiu-min, GAO Zeng-liang. Study on Pull-out Force in Tube-and-Shell Heat Exchangers with Finite Element Method[J]. Nuclear Power Engineering, 2008, 29(6): 58-61.

Study on Pull-out Force in Tube-and-Shell Heat Exchangers with Finite Element Method

  • Received Date: 2008-01-18
  • Rev Recd Date: 2008-05-06
  • Available Online: 2025-07-22
  • Publish Date: 2008-12-15
  • Using the finite element method to shell-and-tube multiple fixed-tube plate heat exchanger in three kinds of cases,the pull-out force for a heat exchanger and tube-sheets under the different temperature distribution are calculated.The results show that the pull-out force have a bigger difference in the different locations of a heat exchanger tube for multiple exchangers.According to the allowable value of ASME,the pull-out force of all heat exchanger tubes and tube-sheet joint for case 3 can meet the requirements,but the pull-out force of the joints with 56 heat exchanger tubes and tube-sheets for case 1 and with 22 heat ex-changer tubes and tube-sheets for case 2 are over the allowable values.Therefore,under the co-action of vi-bration,corrosion and so on caused by the flow of the medium,it is easy for these joints to rupture and leak.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (7) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return