Based on the state equation of ideal gas,the laws of conservation of mass and energy,and the thermophysical properties of water and steam,and assuming that the process of medium change is adiathermal,the design principal and method for capability of the Pressurizer Relief Tank is proposed,and its validity is verified against the parameters of the Pressurizer Relief Tank in operating plants,which shows a good agreement.