  • The calculation formula of neutron pulse count rate was deduced for the weak source reactor using the model of point reactor.Method of blind area confirmation was discussed. The application shows that this method is consistent with the reality and useful for the improvement of the safety of physics star-up, which is applicable in the supervision of critical safety of nuclear activities, such as the maintenance and repair of reactor, loading and unloading of nuclear fuel and storage of fuel element.

     