XU Zhao, WU Xin-xin. Transient Analysis of Residual Heat Removal System Used in 200 MW Low Temperature Heating Reactor[J]. Nuclear Power Engineering, 2008, 29(2): 61-65.
Citation: XU Zhao, WU Xin-xin. Transient Analysis of Residual Heat Removal System Used in 200 MW Low Temperature Heating Reactor[J]. Nuclear Power Engineering, 2008, 29(2): 61-65.

Transient Analysis of Residual Heat Removal System Used in 200 MW Low Temperature Heating Reactor

  • Received Date: 2007-04-11
  • Rev Recd Date: 2007-06-21
  • The residual heat removal system of 200 MW Heating Reactor is constituted by 3 coupled natural circulations.The thermal-hydraulic analysis of the system has been performed in this paper,and the numeric model of the passive residual heat removal system has been constructed based on 1-demansion mass equation,momentum equation and energy equation.The program in this paper has been used to compute the model and simulate the heat removal process of the system.The results show that the heat transfer ability of the system meet the design requirements.

     