Advance Search
Volume 30 Issue 3
Jun.  2009
Turn off MathJax
Article Contents
CENG He-rong, HAN Wei-shi, LIU Yao-guang, QIAN Da-zhi, XU Xian-qi, DUAN Shi-lin. Design of Measurement System for Cross Power Spectrum Density in Reactors[J]. Nuclear Power Engineering, 2009, 30(3): 107-110.
Citation: CENG He-rong, HAN Wei-shi, LIU Yao-guang, QIAN Da-zhi, XU Xian-qi, DUAN Shi-lin. Design of Measurement System for Cross Power Spectrum Density in Reactors[J]. Nuclear Power Engineering, 2009, 30(3): 107-110.

Design of Measurement System for Cross Power Spectrum Density in Reactors

  • Received Date: 2008-03-28
  • Rev Recd Date: 2008-10-15
  • Available Online: 2025-07-28
  • Publish Date: 2009-06-15
  • This paper designs a measurement system based on PXI-1031 high-speed synchronization DAQ. By using Labview8.5 program, the data acquisition and data process and analysis program required by the measurement system is designed. By using Fluke-282 arbitrary waveform generator, two passages of sine signals with 150Hz and 270Hz are produced. By using the data acquisition and data process and analysis program, the cross power spectrum density is calculated for two passages of sine signals. The simulation test results show that the measurement system can meet the design requirement.

     