Analysis of Heat Conduction Performance of Heat Pipe Based on Thermal Resistance Network Method
-
摘要: 为了获得热管温度、传输功率等导热特性,基于热阻等效理论建立了考虑蒸汽腔区域传热的二维热管热阻网络模型,获得了热管瞬态及稳态传热性能,并与文献及本文实验数据进行了对比验证,其绝热段平均温度最大相对误差为7.6%。研究结果表明,模型对文献钠工质热管及本文水工质热管实验数据具有较高的计算精度;热管轴向各段温度均匀性较好,吸液芯径向热阻是热管导热热阻的主要影响因素;热管工作温度与传输功率随冷源参数变化趋势相反,热管传输热量是一个自适应的动态调节过程。因此,热阻网络模型可以作为实验分析和热管设计的工具,同时还可以进一步扩大工况研究范围,获得边界条件对热管传热过程的影响规律,进一步为多应用场景下热管设计提供参考。Abstract: In order to obtain the heat conduction characteristics such as heat pipe temperature and transmission power, a 2D heat pipe thermal resistance network model considering steam cavity heat transfer is established based on the thermal resistance equivalence theory, and the transient and steady-state heat transfer performance of the heat pipe are obtained. The literature and the experimental data of this paper are compared and verified. The maximum relative error of the average temperature in the adiabatic section is 7.6%. The results show that the model has a high accuracy for the experimental data of sodium working medium heat pipe in literature and hydraulic working medium heat pipe in this paper; The temperature uniformity of each axial section of the heat pipe is good, and the radial thermal resistance of the wick is the main factor affecting the thermal-conduction resistance of the heat pipe; The working temperature and transmission power of the heat pipe change with the cold source parameters in the opposite trend, and the heat transfer of the heat pipe is an adaptive dynamic regulation process. Therefore, the thermal resistance network model can be used as a tool for experimental analysis and heat pipe design. At the same time, it can further expand the research scope of working conditions, obtain the influence rules of boundary conditions on heat pipe heat transfer process, and further provide reference for heat pipe design in multiple application scenarios.
-
表 1 热管实验主要参数
Table 1. Main Parameters of Heat Pipe Experiment
参数 参数值 管壳材料 不锈钢 工质种类 去离子水 热管尺寸(直径×壁厚×长度) 25×2.5×1000 蒸发段/mm 400 绝热段/mm 229 冷凝段长度/mm 371 加热方式 等壁温加热:20~290℃ 冷却方式 冷却水对流换热 吸液芯厚度/ mm 0.6 -
[1] 庄骏, 张红. 热管技术及其工程应用[M]. 北京: 化学工业出版社, 2000: 7-8. [2] SVIRIDENKO I I. Heat exchangers based on low temperature heat pipes for autonomous emergency WWER cooldown systems[J]. Applied Thermal Engineering, 2008, 28(4): 327-334. doi: 10.1016/j.applthermaleng.2006.02.033 [3] MOCHIZUKI M, SINGH R, NGUYEN T, et al. Heat pipe based passive emergency core cooling system for safe shutdown of nuclear power reactor[J]. Applied Thermal Engineering, 2014, 73(1): 699-706. doi: 10.1016/j.applthermaleng.2014.07.004 [4] XIONG Z Q, WANG M L, GU H Y, et al. Experimental study on heat pipe heat removal capacity for passive cooling of spent fuel pool[J]. Annals of Nuclear Energy, 2015, 83: 258-263. doi: 10.1016/j.anucene.2015.03.045 [5] KUSUMA M H, PUTRA N, WIDODO S, et al. Simulation of heat flux effect in straight heat pipe as passive residual heat removal system in light water reactor using RELAP5 mod 3.2[J]. Applied Mechanics and Materials, 2016, 819: 122-126. doi: 10.4028/www.scientific.net/AMM.819.122 [6] 孙浩,王成龙,刘逍,等. 水下航行器微型核电源堆芯设计[J]. 原子能科学技术,2018, 52(4): 646-651. doi: 10.7538/yzk.2017.youxian.0465 [7] POSTON D I. The heatpipe-operated Mars exploration reactor (HOMER)[J]. AIP Conference Proceedings, 2001, 552(1): 797-804. [8] PALAC D, GIBSON M, MASON L, et al. Nuclear systems Kilopower overview: GRC-E-DAA-TN29740[R]. Huntsville: NASA, 2016. [9] CAO Y D, FAGHRI A. Transient two-dimensional compressible analysis for high-temperature heat pipes with pulsed heat input[J]. Numerical Heat Transfer, Part A:Applications, 1991, 18(4): 483-502. doi: 10.1080/10407789008944804 [10] FAGHRI A, HARLEY C. Transient lumped heat pipe analyses[J]. Heat Recovery Systems and CHP, 1994, 14(4): 351-363. doi: 10.1016/0890-4332(94)90039-6 [11] 张恒运,葛新石. 两相闭式热虹吸管的集总参数模型研究[J]. 中国科学技术大学学报,1997, 27(2): 174-180. [12] FERRANDI C, IORIZZO F, MAMELI M, et al. Lumped parameter model of sintered heat pipe: transient numerical analysis and validation[J]. Applied Thermal Engineering, 2013, 50(1): 1280-1290. doi: 10.1016/j.applthermaleng.2012.07.022 [13] FAGHRI A. Heat pipe science and technology[M]. Washington: Taylor and Francis, 1995:682-694. [14] ZUO Z J, FAGHRI A. A network thermodynamic analysis of the heat pipe[J]. International Journal of Heat and Mass Transfer, 1998, 41(11): 1473-1484. doi: 10.1016/S0017-9310(97)00220-2 [15] 沈妍,张红,许辉,等. 碱金属热管传热特性的模拟与试验分析[J]. 太阳能学报,2016, 37(3): 644-650. doi: 10.3969/j.issn.0254-0096.2016.03.018 [16] SAAD S M I. Improved transient network model for wicked heat pipes[D]. Hamilton: McMaster Univ. , 2006. [17] 崔迎欢. 热管导热性能及其影响规律研究[D]. 成都: 中国核动力研究设计院, 2021.