Advance Search
Volume 37 Issue 1
Feb.  2025
Turn off MathJax
Article Contents
Wang Yu, Chen Zhihui, Hao Chengming, Sun Yan, Huang Wei. Study on Leak Detection for Passive Residual Heat Remove System[J]. Nuclear Power Engineering, 2016, 37(1): 86-90. doi: 10.13832/j.jnpe.2016.01.0086
Citation: Wang Yu, Chen Zhihui, Hao Chengming, Sun Yan, Huang Wei. Study on Leak Detection for Passive Residual Heat Remove System[J]. Nuclear Power Engineering, 2016, 37(1): 86-90. doi: 10.13832/j.jnpe.2016.01.0086

Study on Leak Detection for Passive Residual Heat Remove System

doi: 10.13832/j.jnpe.2016.01.0086
  • Received Date: 2015-03-31
  • Rev Recd Date: 2015-09-30
  • Available Online: 2025-02-15
  • Heat transfer model of inlet tube is established for Small PWR(ACP100) passive residual heat removal system. The heat transfer mechanism for the leakage of inlet line and passive residual system is researched. The results show that the temperature instrument located more than 0.3 m below the inlet line high point is evaluated sufficient to avoid the effect of the source. It is effective to detect and quantify the leaks by temperature monitor. Increasing the leak rate, the maximum temperature measured by the instrument tends to increase. For the leakage above 8×10-4m3/h, the effect of axial heat flux can be disregarded without affecting significantly the calculation.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (21) PDF downloads(0) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return