Advance Search
Volume 37 Issue 4
Feb.  2025
Turn off MathJax
Article Contents
Xing Ji, Yu Pei, Li Jun. Mitigation and Treatment of Accidents in HPR1000 SGTR[J]. Nuclear Power Engineering, 2016, 37(4): 58-62. doi: 10.13832/j.jnpe.2016.04.0058
Citation: Xing Ji, Yu Pei, Li Jun. Mitigation and Treatment of Accidents in HPR1000 SGTR[J]. Nuclear Power Engineering, 2016, 37(4): 58-62. doi: 10.13832/j.jnpe.2016.04.0058

Mitigation and Treatment of Accidents in HPR1000 SGTR

doi: 10.13832/j.jnpe.2016.04.0058
  • Received Date: 2015-10-08
  • Rev Recd Date: 2016-05-20
  • Available Online: 2025-02-15
  • HPR1000 provides mitigation measures for accidents in SGTR in the design. It can prevent SG overfill and mitigate SGTR accident by many means, such as decreasing the shutoff head of the safety injection pump and providing functions of fast cooling, automatic isolation and automatic control of auxiliary feedwater, and post-accident discharge of the blowdown system. The origin and mitigation measures for HPR1000 SGTR accidents are analyzed, and the process of accident treatment is described. Effectiveness of the mitigation measures to prevent SG overfill is verified, to satisfy the acceptance criteria for the radiological consequence of HPR1000.

     