Advance Search
Volume 38 Issue 6
Feb.  2025
Turn off MathJax
Article Contents
Zeng Wei, Song Danrong, Chen Zhi, Zhu Li, Liu Songtao. Strategy for Loss of Coolant Accident in ACP100+[J]. Nuclear Power Engineering, 2017, 38(6): 72-75. doi: 10.13832/j.jnpe.2017.06.0072
Citation: Zeng Wei, Song Danrong, Chen Zhi, Zhu Li, Liu Songtao. Strategy for Loss of Coolant Accident in ACP100+[J]. Nuclear Power Engineering, 2017, 38(6): 72-75. doi: 10.13832/j.jnpe.2017.06.0072

Strategy for Loss of Coolant Accident in ACP100+

doi: 10.13832/j.jnpe.2017.06.0072
  • Received Date: 2016-11-24
  • Rev Recd Date: 2017-07-09
  • Available Online: 2025-02-09
  • Based on the scheme of the ACP100+ small modular reactor such as the inner PRZ and steel containment, the strategy for the emergency core cooling, pressure controlling in the containment and long-term cooling are proposed. According to the elementary calculation and analysis, the accumulator can be eliminated for the ACP100+ and the safety injection system is simplified. The release of mass and energy can be controlled more easily due to the smaller size of break based on pressure restrained pool and containment pool above the small steel containment. And the long-term residual heat can the taken out through the pool above the containment based on the natural convection and the inherent safety can be enhanced.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (27) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return