Fu Jiang, Zhang Lanqi, Tao Guoliang, Xiang Fangcheng, Liu Shengzhi, Chu Xiangnan, Wang Xiaojun, Yin Yulong. Research on Improvement of Pilot Solenoid Valve for Emergency Diesel Generator in Nuclear Power Plant[J]. Nuclear Power Engineering, 2023, 44(6): 226-230. doi: 10.13832/j.jnpe.2023.06.0226
Citation: Fu Jiang, Zhang Lanqi, Tao Guoliang, Xiang Fangcheng, Liu Shengzhi, Chu Xiangnan, Wang Xiaojun, Yin Yulong. Research on Improvement of Pilot Solenoid Valve for Emergency Diesel Generator in Nuclear Power Plant[J]. Nuclear Power Engineering, 2023, 44(6): 226-230. doi: 10.13832/j.jnpe.2023.06.0226

Research on Improvement of Pilot Solenoid Valve for Emergency Diesel Generator in Nuclear Power Plant

doi: 10.13832/j.jnpe.2023.06.0226
  • Received Date: 2022-12-22
  • Rev Recd Date: 2023-03-03
  • Publish Date: 2023-12-15
  • The pilot solenoid valve used in the compressed air start-up system of emergency diesel generator in nuclear power plant fails frequently, and the failure modes are mainly manifested as inability to switch normally and jamming and air leakage. This failure will affect the reliability and availability of the compressed air start-up system of diesel generator and directly lead to the failure of diesel generator to start. In order to solve this problem, the defects in the structural design of the pilot solenoid valve were found through functional testing and disassembly, and it was clear that the root cause of the failure was the unreasonable reset structure of the pilot solenoid valve. The improvement measures mainly include the improvements of the main valve body structure, spool assembly interference structure, main spool guide structure, main spool return spring, diameter of the moving iron core crimping nozzle and the coil power of the pilot solenoid valve. The improved solenoid valve successfully completed all qualification tests. The test results show that the improved solenoid valve solves the failure of normal switching and jamming and air leakage, and improves the reliability of the air starting circuit of the emergency diesel generator.

     

  • loading
  • [1]
    广东核电培训中心. 900 MW压水堆核电站系统与设备[M]. 北京:中国原子能出版社,2007:544-559.
    [2]
    中华人民共和国工业和信息化部. 工业过程控制系统用电磁阀:JB/T 7352—2010[S]. 北京:机械工业出版社,2010:2-11.
    [3]
    黄伟杰,张宓,张云波,等. 核电厂数字化仪表控制系统设备鉴定方法研究[J]. 核动力工程,2014,35(6):111-114.
    [4]
    AFCEN. Design and construction rules for electrical equipment of nuclear island: RCC-E[S]. France: AFCEN, 2005.
    [5]
    国家能源局. 核电厂安全级阀门驱动装置用电磁阀鉴定规程:NB/T 20206—2013[S]. 北京:核工业标准化研究所,2013:19.