Luo Fengyan, Li Wenqiang, Zhang Qingyu, Wang Guohua, Guo Jinxuan. Determination of Trace Arsenic, Plumbum, Stannum and Stibium in Nickel-Based Alloys by Inductively Coupled Plasma Mass Spectrometry[J]. Nuclear Power Engineering, 2023, 44(S2): 211-215. doi: 10.13832/j.jnpe.2023.S2.0211
Citation: Luo Fengyan, Li Wenqiang, Zhang Qingyu, Wang Guohua, Guo Jinxuan. Determination of Trace Arsenic, Plumbum, Stannum and Stibium in Nickel-Based Alloys by Inductively Coupled Plasma Mass Spectrometry[J]. Nuclear Power Engineering, 2023, 44(S2): 211-215. doi: 10.13832/j.jnpe.2023.S2.0211

Determination of Trace Arsenic, Plumbum, Stannum and Stibium in Nickel-Based Alloys by Inductively Coupled Plasma Mass Spectrometry

doi: 10.13832/j.jnpe.2023.S2.0211
  • Received Date: 2023-07-11
  • Rev Recd Date: 2023-09-26
  • Publish Date: 2023-12-30
  • In order to accurately determine trace arsenic, plumbum, stannum and stibium in the nickel-based alloy (NBS), inductively coupled plasma mass spectrometry (ICP-MS) was used. The HNO3-HCl system was used for airtight digestion of NBS, and the isotope mass numbers were selected as 75, 208, 120, and 121 respectively. The kinetic energy discrimination (KED) mode was used to overcome the mass spectral interference, and the internal standard element 89Y was used to monitor the stability of the instrument and the matrix effect online. A method for the determination of arsenic, plumbum, stannum and stibium in nickel-based alloy was established. Under the optimized conditions, the signal intensities of each element had a good linear relationship with the corresponding mass concentrations, and the linear correlation coefficient was greater than 0.9999. When the sample weight was 0.1 g, the detection range of of the four elements was 10.0-200.0 μg/g. The detection limit of each element was better than 0.15 ng/mL, and the recovery rate of standard addition was between 85%-120%. The relative standard deviation (n=6) of the spiked sample was 2.8%-5.6%. This method has good sensitity, precision and accuracy, and can be used for the determination of arsenic, plumbum, stannum and stibium in NBS.

     

  • loading
  • [1]
    陈国良. 高温合金学[M]. 北京: 冶金工业出版社,1988 .
    [2]
    梁爽,刘智鑫,李秋鹤. 镍基高温合金的发展综述[J]. 山东工业技术,2016(4): 34.
    [3]
    唐中杰,郭铁明,付迎,等. 镍基高温合金的研究现状与发展前景[J]. 金属世界,2014(1): 36-40.
    [4]
    邵晓东,刘养勤,李瑛,等. 镍基合金中元素分析方法研究进展[J]. 冶金分析,2010, 30(5): 38-48. doi: 10.3969/j.issn.1000-7571.2010.05.009
    [5]
    刘正,王海舟,李小佳,等. 第三液相富集-石墨炉原子吸收光谱法测定高温合金中痕量碲[J]. 冶金分析,2016, 36(5): 1-6.
    [6]
    杨倩倩,何淼,彭霞. 电感耦合等离子体原子发射光谱(ICP-AES)法测定高温合金中5种非金属元素[J]. 中国无机分析化学,2015, 5(4): 53-55. doi: 10.3969/j.issn.2095-1035.2015.04.012
    [7]
    高辉,邓秀琴,贺小平. MPT-AES测定镍基合金中的铁[J]. 应用化工,2014, 43(10): 1925-1927.
    [8]
    安身平,王树安,廖志海,等. X射线荧光光谱法测定镍基合金中镍、铬、钼、铌含量[J]. 理化检验(化学分册),2009, 45(11): 1339-1340,1342.
    [9]
    赵华,李本涛,冯典英. 电感耦合等离子体质谱法痕量成分定值技术研究进展[J]. 化学分析计量,2007, 16(5): 77-80. doi: 10.3969/j.issn.1008-6145.2007.05.025
    [10]
    张桢,刘巍,郭颖. 电感耦合等离子体质谱法测定镍基高温合金中10种元素[J]. 理化检验(化学分册),2016, 52(10): 1201-1205.
    [11]
    AGATEMOR C, BEAUCHEMIN D. Matrix effects in inductively coupled plasma mass spectrometry: a review[J]. Analytica Chimica Acta, 2011, 706(1): 66-83. doi: 10.1016/j.aca.2011.08.027
    [12]
    MCLEOD C W, DATE A R, CHEUNG Y Y. Metal oxide ions in inductively coupled plasma-mass spectrometric analysis of nickel-base alloys[J]. Spectrochimica Acta Part B:Atomic Spectroscopy, 1986, 41(1-2): 169-174. doi: 10.1016/0584-8547(86)80148-3