Fang He, Wei Luo, Wan Chenghui, Gao Yiyuan, Li Zaipeng. Research and Engineering Application of Xenon Dynamic-Flux Measurement Method for M310 Unit Based on Bamboo-C Code[J]. Nuclear Power Engineering, 2024, 45(1): 11-18. doi: 10.13832/j.jnpe.2024.01.0011
Citation: Fang He, Wei Luo, Wan Chenghui, Gao Yiyuan, Li Zaipeng. Research and Engineering Application of Xenon Dynamic-Flux Measurement Method for M310 Unit Based on Bamboo-C Code[J]. Nuclear Power Engineering, 2024, 45(1): 11-18. doi: 10.13832/j.jnpe.2024.01.0011

Research and Engineering Application of Xenon Dynamic-Flux Measurement Method for M310 Unit Based on Bamboo-C Code

doi: 10.13832/j.jnpe.2024.01.0011
  • Received Date: 2023-03-29
  • Rev Recd Date: 2023-05-26
  • Publish Date: 2024-02-15
  • In order to optimize the current technical requirements of M310 unit, i.e. to wait for 24 h after the power increases to the specified power level to perform in-core flux measurement test, so as to further improve the economy of PWR nuclear power plant, a new method for core flux measurement under dynamic xenon conditions is developed based on Bamboo-C, an advanced PWR core physical analysis software independently developed by Xi'an Jiaotong University. Based on the dynamic xenon flux measurement data, the measured values of core power distribution under the condition of balanced xenon were predicted, and the engineering application was verified in the overhaul of Tianwan No.5 unit. The verification results show that the dynamic xenon flux measurement method proposed in this paper can shorten the waiting time of xenon balance to 2 h at a specified power level, and has high prediction accuracy for key physical quantities in the core.

     

  • loading
  • [1]
    沈聪. 320MWe核电机组75%功率平台试验前稳定时间优化[J]. 科技视界,2018(1):7-10. doi: 10.3969/j.issn.2095-2457.2018.01.003
    [2]
    杨庆湘,王丽华,姜赫,等. 压水堆核电厂换料物理启动试验优化研究和应用实践[J]. 核科学与工程,2016,36(5):617-623. doi: 10.3969/j.issn.0258-0918.2016.05.007
    [3]
    郭建,曹云龙. 北方某核电厂升功率物理试验优化的论证及实施[J]. 核科学与工程,2017,37(3):514-519. doi: 10.3969/j.issn.0258-0918.2017.03.027
    [4]
    胡娟,李振振,孟凡锋. M310机组堆芯功率分布试验Fxy验收准则分析[J]. 商品与质量,2018(50):164-166. doi: 10.3969/j.issn.1006-656X.2018.50.154
    [5]
    詹勇杰. 秦山第二核电厂物理启动试验优化探讨[D]. 上海:上海交通大学,2008.
    [6]
    LEE K, KIM C H. The least-squares method for three-dimensional core power distribution monitoring in pressurized water reactors[J]. Nuclear Science And Engineering, 2003, 143(3): 268-280. doi: 10.13182/NSE03-A2335
    [7]
    RAMEZANI I, GHOFRANI M B. Reconstruction of neutron flux distribution by nodal synthesis method using online in-core neutron detector readings[J]. Progress in Nuclear Energy, 2021, 131: 103574. doi: 10.1016/j.pnucene.2020.103574
    [8]
    万承辉,李云召,郑友琦,等. 压水堆燃料管理软件Bamboo-C研发及工业确认[J]. 核动力工程,2021,42(5):15-22. doi: 10.13832/j.jnpe.2021.05.0015