Abstract:
At the start-up stage of pressurized water reactor(PWR)nuclear power station,the primary loops shall be degasified. Compared with the traditional degas method, the primary loops vacuum degas technology can not only shorten the test time, also greatly reduce the risk of the primary pump at the first starting. Technology of the primary loop vacuum degas is widely used in starting-up of the CPR1000 unit, after many tests and continuous improvement, this technology has been well established. Technology of the primary loops vacuum degas technology is introduced in this paper.