Theoretical Calculation and Modeling Analysis of Pump Comprehensive Performance Test of Auxiliary Feed Water System[J]. Nuclear Power Engineering, 2018, 39(6): 101-103. doi: 10.13832/j.jnpe.2018.06.0101
Citation: Theoretical Calculation and Modeling Analysis of Pump Comprehensive Performance Test of Auxiliary Feed Water System[J]. Nuclear Power Engineering, 2018, 39(6): 101-103. doi: 10.13832/j.jnpe.2018.06.0101

Theoretical Calculation and Modeling Analysis of Pump Comprehensive Performance Test of Auxiliary Feed Water System

doi: 10.13832/j.jnpe.2018.06.0101
  • Publish Date: 2018-12-15
  • When the results of the pump comprehensive performance test of the auxiliary feedwater system (ASG) of CPR1000 do not satisfy the supervision requirements, the throttle elements in the pipeline system need to be adjusted. This paper gives a brief description of the adjustment principle of the throttling element. The methods of the theoretical calculation of engineering fluid mechanics and computational fluid dynamics (CFD) provide two ways to obtain the adjustment of the throttling element results. The comparison between two analytical methods shows that the theoretical calculation results are consistent with the modeling analysis results. According to the respective characteristics of theoretical calculation and modeling analysis, the most convenient method can be selected according to the actual needs.

     

  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (116) PDF downloads(1) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return