Advance Search
Volume 42 Issue 6
Dec.  2021
Turn off MathJax
Article Contents
Huang Zhigang, Zhang Yan, Peng Chuanxin, Zan Yuanfeng, Zhuo Wenbin, Yan Xiao. Experimental Study on Pressurizer Surge Line Double-Ended Break of Small Reactor[J]. Nuclear Power Engineering, 2021, 42(6): 82-86. doi: 10.13832/j.jnpe.2021.06.0082
Citation: Huang Zhigang, Zhang Yan, Peng Chuanxin, Zan Yuanfeng, Zhuo Wenbin, Yan Xiao. Experimental Study on Pressurizer Surge Line Double-Ended Break of Small Reactor[J]. Nuclear Power Engineering, 2021, 42(6): 82-86. doi: 10.13832/j.jnpe.2021.06.0082

Experimental Study on Pressurizer Surge Line Double-Ended Break of Small Reactor

doi: 10.13832/j.jnpe.2021.06.0082
  • Received Date: 2020-10-30
  • Rev Recd Date: 2021-04-30
  • Publish Date: 2021-12-09
  • Accident response characteristics of the passive safety system and the parameter variation of the primary loop system were obtained through the experimental study of double-ended break of modular small reactor pressurizer surge line . The results show that under the extreme condition of double-ended break of the pressurizer surge line, the MP accumulator can provide a large stable safety injection flow in a short time to replenish the water capacity of the system in time; The operation process of the HP safety injection system is relatively complex, and the safety injection flow rate is closely related to the medium state of the pressure balance pipeline of the core makeup tank and the operation state of the MP safety injection system, and it is in the state of intermittent injection within 1.7 hours. During the whole accident process, the core has been submerged. The modular small reactor passive safety system can ensure the core safety under the extreme condition of double-ended break of pressurizer surge line.

     

  • loading
  • [1]
    VLADIMIR K. Small and medium sized reactors: development status and deployment potential/iaea activities in support of smr development and deployment[C]//INPRO/SMR Briefing, IAEA, 30 September, USA, 2008.
    [2]
    金远,蒋孝蔚,邓坚,等. 小破口失水事故非能动系统瞬态特性研究[J]. 核动力工程,2020, 41(2): 189-192.
    [3]
    曾未,宋丹戎,陈智,等. ACP100+失水事故应对策略研究[J]. 核动力工程,2017, 38(6): 72-75.
    [4]
    彭传新,鲁晓东,张妍,等. 波动管小破口失水事故实验研究[J]. 核动力工程,2016, 37(5): 63-67.
    [5]
    黄志刚,彭传新,张妍,等. 安注管道不同破口尺寸条件下非能动安注系统运行特性试验研究[J]. 核动力工程,2017, 38(4): 70-75.
    [6]
    彭传新,张妍,黄志刚,等. DVI管小破口失水事故实验研究[J]. 原子能科学技术,2016, 50(10): 1787-1792. doi: 10.7538/yzk.2016.50.10.1787